●Measurement examination of the structure
●Inspection of the structure
●Investigation, diagnosis of the structure
●3D measurement
○Sale of the Three-dimensional measurement machine
-- - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Bridge inspection

Road maintenance advanced with rapid economic growth, and many bridges were built to date.
 
I secure security, smooth traffic of Hashigami and, not to make any giving damage to roadside and a third party, am an act to improve maintenance and the durability of the load power of the bridge-resistant, and to utilize a bridge effectively namely maintenance.
 
In maintenance maintenance, check, an investigation, repair, reinforcement and the record of the series in the maintenance drift, but enumerate it concretely, and explain check, the investigation of the bridge as the duties that we specialize.

Inspection method

I carry out inspection, an investigation using a check machine and a Bridge inspection car by proximity viewing as needed mainly. In addition, I say an examination of hammering and swat the surface of the concrete of the neighborhood of surface of the concrete structure with a hammer and grasp a state by the sound that occurred. I judge it by making a low sound when a high-pitched sound includes detachment or a cavity when concrete is healthy.
Check method photograph
Check method photograph
Check method photograph

I classify kinds of the damage

I classify corrosion and a crack of the steel, crazing of the concrete, kinds of the damage including the irregularities of the road surface.

Judgment of the measures division

I judge a structural material and the measures division of the damage kind and carry out the identification of the damage cause after carrying out inspection as needed, and having grasped the damage situation after a check result.

Record of the result

I make an above-mentioned result with the form that the visitor wishes for as a inspection record and a management medical record and submit it.
 The inquiry is this
Engineering department one section charge: Sato
Back to TOP